Chapter 23: Configuring Frame Relay Interworking

Avidia System Configuration and Management User Manual

473

d

In the

Committed Burst

box, type the committed burst value in data bits. The valid range

is 0 to 144000, with 0 as the default.

Committed Burst is the maximum number of data bits that the network will transfer
under normal conditions during the measurement interval.

e

In the

Throughput

box, type the throughput value in seconds. The valid range is 0 to

144000, with 0 as the default.

Throughput is the average number of data bits transferred per second across the
network interface in one direction.

7

In the

Interworking

section, select the frame relay interworking standard (

FRF.5

or

FRF.8

).

Frame relay interworking allows frames to be transported by an ATM network to an ATM
device or another frame relay device. There are two standards for interworking:

FRF.5

defines how frames are encapsulated so that they can be carried by the ATM

network to another frame device. If you select this option, proceed to

Step 8

.

FRF.8

defines how frames are translated between ATM and frame devices. If you select

this option, skip to

Step 9

.

8

If you selected Interworking

FRF.5

, do the following:

a

In the

Rx LP Mode

box, select the Rx LP mode (

1

or

2

).

The Rx LP mode determines the loss priority settings when transmitting from ATM to
frame relay.

1

—The frame relay header DE field is set if the CLP field of one or more ATM cells

of a frame is set to 1 or if the FR-SSCS PDU header DE field is set to 1.

2

—The frame relay header DE field is copied into the FR-SSCS PDU header DE field,

independent of the ATM CLP field value received.

b

In the

Tx LP Mode

box, select the Tx LP Mode (

1

or

2

).

The Tx LP mode determines the content of the FR-SSCS PDU header DE and ATM
cell ATM CLP fields.

1

—The frame header DE field is copied in the FR-SSCS PDU header DE field and

mapped into the ATM CLP field of every ATM cell generated by the frame.

2

—The frame header DE field is copied into the FR-SSCS PDU header DE field. The

ATM CLP field of every ATM cell generated by the segmentation process of the
AAL5 PDU containing the information of that frame is set to the CLP Mask value.