ADC AVIDIA SWD4573I1 User Manual

Page 588

Advertising
background image

Configuring and Initiating OAM Loopbacks

562

Avidia System Configuration and Management User Manual

5

In the

Function Type

box, select the loopback type (

Segment

or

End-To-End

).

Segment loopbacks test the connectivity between any two uniquely addressable points in a
VPC or VCC.

End-to-end loopbacks test the connectivity between any uniquely addressable point in the
VPC or VCC and any end point (such as a modem or a network end point) where a VPC or
VCC terminates.

6

In the

Destination Location ID

box, type the OAM Location ID of the target device where the

cells will be looped back to the originating device (format xx:xx:xx:xx:xx:xx:xx:xx:
xx:xx:xx:xx:xx:xx:xx:xx
where x is an integer 0 - 9 or an alpha character a - f). It is not
necessary to modify this value when you perform a loopback test to a Megabit Modem.

7

In the

Count

box, type the total number of cells to be sent in the loopback (cells are sent one

at a time).

8

In the

Time Out (sec)

box, type the number of seconds allowed for the looped back cells to

return to the originating device before the loopback is designated as failed.

9

In the

Delay (sec)

box, type the number of seconds the system to waits between transmitted

cells.

10

In the

Loopback Completion Trap

box, select

Send

to send a trap when the loopback is

completed or select

Do Not Send

if you do not want the management card to send a trap.

11

Do one of the following:

To activate the settings and close the

Add OAM Loopback Entry

window, click

Set

, then in

the confirmation dialog click

Back

.

To return to the

OAM Loopback Table

window without deleting the table entry, click

Cancel

.

Advertising