Examples

::ds3=> show 4.1

::ds3=> show

The following screen illustrates an example of a show ds3 command.

Information

Descriptions

Time Elapsed

The number of seconds that have elapsed since the current
15-minute data collection period began.

Valid Intervals

The number of 15-minute data collection intervals for which
data is collected. The Avidia system supports 96 intervals, or
24 hours, of data collection.

Line Type

The type of DS3 line. Options:

dsx3m23

dsx3CbitParity (this line type is not currently supported)

Line Coding

The type of coding on the line. B3ZS is the only line type
currently supported.

Send Code

The type of data currently being transmitted. Currently, only
SendNoCode is supported, indicating that the line is sending
looped or normal data.

::ds3=> show 12.1

THE DS3 CONFIGURATION TABLE FOR PORT 12.1

Time Elapsed:

3213

Valid Intervals:

96

Line Type:

CbitParity

Line Coding:

B3ZS

Send Code:

SendNoCode

Circuit Identifier:

Cell Scrambling :

Enabled

Framing Mode :

Direct

Line Status:

LOS

Transmit Clock Source:

localTiming

Invalid Intervals:

0

LBO:

0 to 225 feet

Line Status Last Change:

Wed, Dec 06 2000 11:19:19

Line Status Change Trap Enable:

Enabled

Loop Back Status:

NoLoopback

Channelization:

disabled

Ds1 For Remote Loop:

1