4 user setup and calibration, 1 initial end user setup, System power check – Hale FoamLogix 6.5 User Manual

Page 109: User setup and calibration, 4user setup and calibration

Advertising
background image

Se tup and Cal ibration

109

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

4

User Setup and Calibration

4.1

INITIAL END USER SETUP

When the apparatus is delivered to the end
user facility the foam tank(s) must be filled
with the specified foam concentrate(s).
Make sure the proper foam concentrate is
put into the correct tank. The system must
then be adjusted to operate with the end
user foam concentrate(s) for best accuracy.
Also see heading “Appendix A: Foam Con-
centrate Compatibility” on page 149.

System Power Check

Observe the display on the control
unit while energizing the apparatus
electrical system. On initial power
up of the apparatus, the Hale Foam-
Logix system begins a brief self-
diagnostic routine. When com-
pleted, the system enters the
STANDBY or System Ready mode.
(See Figure 4-1: “Initial Start-Up,
System Ready Displays.”)

Check the control unit readout —
FLOW, TOTAL FLOW, % FOAM,
TOTAL FOAM
and that all bar
graph LEDs illuminate along with
88888 for several seconds.

HALE CLASS 1 2002, followed by
the software revision level (e.g., r
x.x
) scrolls across the display dur-
ing the self-diagnostics, followed by
the default display. The default dis-
play is zero on the digital readout (if
no water is flowing) and FLOW LED. (See Figure 4-1: “Initial Start-Up, Sys-
tem Ready Displays.”)

If the system ready display does not appear, see Section “7 Troubleshoot-
ing” on page 141 for more information.

Figure 4-1: Initial Start-Up, System

Ready Displays