High ambient temperature message – Hale FoamLogix 6.5 User Manual

Page 127

Advertising
background image

127

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

Ope ra tion

If the system operates for a period of thirty (30) seconds without a feedback
signal the system switches to the STANDBY mode and the display flashes
no Pr (no prime), indicating there is no foam concentrate flow.

High Ambient Temperature Message

(See Figure 5-5: “Priming,
HIGH Temperature and
LOW Battery Messages.”)

If the Hale FoamLogix sys-
tem is operating in an envi-
ronment of excessive
ambient temperatures, the
display shows HIGH.

If the circuitry in the Hale
FoamLogix system is being
affected by a drop in power
supply voltage the display
shows Lo SP.

Note: This is not necessarily
an indication of apparatus
battery level or condition. It
is only an indication of
adverse system operating
conditions. For instance, a
bad battery cable can cause
the system to see LOW
power even though the bat-
teries are fully charged.

In either case the system
continues to run. If condi-
tions deteriorate to the point
of potential system dam-
age, due to heat or low
power, the system switches
to the STANDBY mode and
the error message remains
until ON is pressed again.

Figure 5-5: Priming, HIGH Temperature and

LOW Battery Messages

Advertising