6 electrical – Hale FoamLogix 6.5 User Manual

Page 85

Advertising
background image

85

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

Ele c tri ca l Ins ta lla tion

3.6

ELECTRICAL

See Figure 3-32: “Single Tank Electrical Harness Overview,” on page 87.
Also see Figure 3-33: “Dual Tank Electrical Harness Overview” on page 88.

Complete system electrical diagrams are provided at the end of this man-
ual. Refer to these diagrams for proper installation of each of the electrical
components.

The Hale FoamLogix 3.3, 5.0 or 6.5 system is designed to be installed with
a minimum of electrical connections. Cables are provided with each Hale
FoamLogix system to make the flow sensor, control unit and motor distribu-
tion box connections.

The system installer must supply primary power wire, low tank level sensor
wire and flat braided ground straps.

CAUTION !

Review the “Safety” section of this manual, beginning on page 13,
in its entirety before proceeding with electrical connections.

To prevent system damage or electrical shock the main power sup-
ply wire must be the last connection made to the Hale FoamLogix
motor distribution box. Also see heading “Hale Foam System Lay-
out Drawings” on page 39.

The cables provided with each Hale FoamLogix system contain
shielded assemblies.

NEVER attempt to shorten or lengthen these shielded cables.

If necessary order longer or shorter cables from Hale Products to
suit your particular installation.

The cables are indexed so they connect to the correct receptacle
one way only. The cables shipped with each Hale FoamLogix sys-
tem are tested at the factory with the specific unit. When making
cable connections DO NOT force mismatched connections as dam-
age can result, causing improper system operation.

The system can only perform when electrical connections are
sound.

Make sure each electrical connection is correct.

Hale FoamLogix systems are designed for use on direct current,
negative (–) ground apparatus electrical systems only.

Do not mount a radio transmitter or transmitter cables in direct or
close contact with the Hale FoamLogix unit.

Advertising