This hose is used for calibrat-
ing the foam pump, pumping
the concentrate into a con-
tainer to empty the foam tank
or to assist in priming of the
foam pump. The hose from
the BYPASS port, must be
long enough to reach a con-
tainer outside the truck.

Note: If the handle or placard
is removed from the bypass
valve for repairs or to facilitate
remote mounting make sure
they are installed on the valve
correctly. Make sure the tang
on the handle engages the
cast stops. (See Figure 3-21:
“Bypass Valve Assembly.”)

ADT Option Air Connections

If the ADT option is used, install the operating switch and indicator light
placard on the apparatus operator panel. A mounting cutout diagram is pro-
vided. (See Figure 3-22: “ADT Option Panel Placard Layout Dimensions.”)

After mounting the placard assembly install the air hoses from the ADT to
the placard assembly. Make sure proper connections are made at the plac-
ard assembly. (See Figure 3-23: “ADT Air Hose Connections, Part 1,” on
page 74.)

A color coded decal attached to the ADT valve assembly along with an
optional color coded air hose harness simplifies air hose connections. If the
optional air hose harness is not used, 1/4” (6mm) inside diameter air brake
tubing can be substituted. Make sure the air brake tubing selected has the
proper DOT approval.

(See Figure 3-23: “ADT Air Hose Connections, Part 1,” on page 74.) Also
see Figure 3-24: “ADT Option Air Hose Connections, Part 2” on page 75.

When cutting the air harness or air brake tubing to size make sure the ends
are square using a tubing cutter or razor knife.