Figure 3-13: flow sensor/saddle clamp installation, Foam pump flush system, Dual tank system – Hale FoamLogix 6.5 User Manual

Page 65: Single tank system, No tank option

Advertising
background image

65

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

Ins ta lle r Ins ta lla tion

Align the indexing pin of the saddle
clamp to the indexing hole of the
spacer to align the saddle clamp
mount. Secure with four 1/2”
(13mm) machine screws, without
lock washers. Torque to 8.5 in.-
lbs. (1.0 N-m).

Align the paddle wheel indexing
pin to the indexing hole in the
spacer and secure using four 3/4”
screws and lock washers. Torque
to 7.5 in.-lbs.
(0.9 N-m).

Apply a small amount of grease to
the saddle clamp gasket before
the final installation of the assem-
bly onto the pipe. Firmly tighten
the saddle clamp onto the pipe.

Foam Pump Flush System

Dual Tank System

Flushing water must be provided to flush the system of foam concentrate
after each use. This prevents adverse reactions of some foam concentrates
should they mix together. The Hale ADT and MDT II each have provisions
for connecting flushing water to the foam concentrate injection system.

Single Tank System

The Hale MST provides a selector valve and gives the system flush capabil-
ities for NFPA compliance. A fitting provided on the Hale MST simplifies the
flushing water connection.

No Tank Option

The system installer must provide a flushing water supply to comply with
NFPA standards.

The flushing water hose must be a minimum of 1/2” (12 mm) inside diame-
ter and capable of withstanding the maximum fire pump discharge pressure,
500 PSI (34 BAR) minimum. The flush water supply should be provided
from one of the pressure taps on the discharge of the fire pump.

Figure 3-13: Flow Sensor/Saddle Clamp

Installation

Advertising
This manual is related to the following products: