Hale FoamLogix 6.5 User Manual

Page 86

Advertising
background image

Electrical Installation

86

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual

p/n: 029-0021-68-0

CAUTION ! - continued

Before connecting the cables, inspect the O-ring seal in the female
connector. If the seal washer is missing or damaged, water can
enter the connector causing corrosio, resulting in possible system
failure.

The ground strap must be a minimum of 1-1/4” (32mm) wide and no
longer than 18” (457mm).

A longer ground strap must be wider or a double thickness strap
must be used.

Make sure the ground strap is attached to the chassis frame.
Grounding to the body IS NOT acceptable.

Always disconnect the power cable, ground straps, electrical wires
and cables from the control unit or other Hale FoamLogix equip-
ment before electric arc welding at any point on the apparatus.

Failure to do so could result in a power surge through the unit that
could cause irreparable damage.

There are no user serviceable parts inside Hale FoamLogix system
electrical/electronic components. Opening of these components
(motor distribution box or control unit) voids the warranty.

Advertising
This manual is related to the following products: