Figure 3-37: low level sensor mounting options, Figure 3-38: side mount sensor location dimensions – Hale FoamLogix 6.5 User Manual

Page 93

Advertising
background image

93

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

Ele c tri ca l Ins ta lla tion

CAUTION !

FOAM TANK LOW LEVEL
SENSORS MUST BE USED
TO PROTECT THE HALE
FOAMLOGIX FROM DRY
RUNNING. FAILURE TO
USE LOW LEVEL SEN-
SORS WITH THE HALE
FOAMLOGIX SYSTEM
VOIDS THE WARRANTY.

Side Mount Installation

A side mount low tank level
sensor is used if the bot-
tom of the foam tank is not
accessible.

1.

The sensor has
1/2” (13mm)
NPT threads. If
tank design and
construction
allows, the side
mount sensor is
threaded
directly into the
side of the tank
at the proper
height. (See
Figure 3-38:
“Side Mount
Sensor Loca-
tion Dimen-
sions.”)

Also, the sensor can be mounted on the foam tank using a 1/2” x 1” (13
x 25mm) NPT bushing and a bulkhead fitting with 1” (25mm) FNPT
threads.

2.

The center of the switch must be located at least 1-½ to 2 inches (38 to
51 mm) from the bottom of the foam tank with the float positioned on top
of the switch to allow up and down movement.

Figure 3-37: Low Level Sensor Mounting Options

Figure 3-38: Side Mount Sensor Location Dimensions

Advertising