Figure 3-40: top mount low level sensor assembly, Low level sensor wiring, 6 electrical - continued – Hale FoamLogix 6.5 User Manual

Page 97

Advertising
background image

97

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

Ele c tri ca l Ins ta lla tion

10.

Install and
tighten the 5/
8” (16mm)
tube compres-
sion nut.

11.

Slide the 1/2”
diameter tube
in the 5/8”
(16mm) diam-
eter tube and
adjust the tele-
scoping sec-
tion until the
desired length
is achieved, as
measured
from the bot-
tom of the
flange to the
bottom of the
sensor.
Tighten the
compression
fittings on the
union to lock
length setting.

12.

Tighten the
strain relief
gland nut and
strain relief.

Low Level Sensor Wiring

CAUTION !

WHEN EXTENDING THE LOW TANK SENSOR WIRES MAKE SURE THE
SPLICES ARE PROPERLY SEALED USING AN ADHESIVE FILLED HEAT
SHRINK TUBING.

Figure 3-40: Top Mount Low Level Sensor Assembly