FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

Ope ra tion

3. Energize the apparatus electrical system and press Hale FoamLogix DISPLAY

button to turn ON the system.

4. The Hale FoamLogix enters the STANDBY mode. (See Chapter 4, Figure 4-

7: “Simulated Flow Calibration,” on page 115.)

5. When the FLOW LED illuminates, press and release the and buttons

simultaneously.

6. The display shows S 150 (or other preset default value) and the FLOW LED

illuminates. (See Figure 5-7: “Simulated Flow Display Sequence,” on page
132.)

7. Press the ON button. The left-most LED on the bar graph illuminates and the

foam pump begins running.

8. Foam concentrate flows out of the end of the bypass hose.

To End Simulated Flow

a.

Press the ON button to STOP the foam pump.

b.

Press the DISPLAY button (

i

) button until the FLOW LED illuminates.

c.

Press and release the and buttons simultaneously. The display
shows the current water flow value and the FLOW LED illuminates.

d.

De-energize the apparatus electrical system.

e.

Place the bypass valve to the INJECT position.

f.

Secure bypass hose in the appropriate compartment.

g.

Return apparatus to normal ready condition.

5.10

DUAL TANK SYSTEM SELECTION

The following procedures are provided for operation with the Hale ADT or
MDT II Selectors.