Figure 3-5: base plate mounting hole locations – Hale FoamLogix 6.5 User Manual

Page 58

Advertising
background image

Installer Installation

58

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual

p/n: 029-0021-68-0

Position the foam pump so the bypass valve is easily accessible. When the
Hale FoamLogix system is ordered without the ADT option, a separate
bypass valve is included that may be removed from the foam pump and
mounted on a truck panel for easier access.

When ordered with the ADT option, the operating knob may be removed
from the bypass valve actuator and an extension rod installed to permit
remote operation. In either instance, the foam pump and motor assembly
must be located to permit proper operation of the bypass valve.

Make sure the foam concentrate hoses are properly routed to the inlet and
outlet on the foam pump. Foam concentrate must gravity feed to the foam
pump inlet from the foam tank(s).

The foam pump must be mounted in an area to avoid excessive engine
exhaust system heat or accessory heat buildup.

The base of the foam pump and motor assembly includes 5/16” (8mm)
diameter predrilled mounting holes. The apparatus mounting location must
to be drilled accordingly. The base plate may be used as a template to
mark mounting hole location. (See Figure 3-5: “Base Plate Mounting Hole
Locations.”)

Figure 3-5: Base Plate Mounting Hole Locations