Electrical Installation

98

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual

p/n: 029-0021-68-0

Single Foam Tank System

For cable harness overviews, see Section 9 “ 9 Plate Drawings,” on page
170. A
lso see Figure 3-32: “Single Tank Electrical Harness Overview” on
page 87.

Use a minimum 16 AWG type SXL or GXL (SAE J1128) wire to extend the
low tank sensor wire to the 2-pin Packard WeatherPack connector C10 of
the main cable harness. Low tank level sensors are not polarity sensitive
therefore terminal connections are not specific.

When splicing wires make sure the splices are sealed using an adhesive
filled heat shrink tubing. Where two wires exit the heat shrink tubing pinch
the tubing while heating the it to make sure the adhesive seals around both
wires.

CAUTION !

USE THE SILICONE SEALER PROVIDED TO INSULATE AND PREVENT
CORROSION.

A connector kit (Hale p/n: 546-1780-00-0) is available that contains a Pack-
ard WeatherPack 2-contact shroud half, two (2) 14-16 gauge male terminals
and two (2) 14-16 gauge cable seals. Assemble these components to the
end of the low tank sensor wires.

Snap the two halves of the WeatherPack connector together making sure
they are sealed.

Note: If a Hale MST is not used, install the tank select jumper plug, Hale p/n:
513-0320-23-0, to connector C8. (See Figure 3-32: “Single Tank Electrical Har-
ness Overview” on page 87.)

Dual Foam Tank System

For cable harness overviews, see Section 9 “ 9 Plate Drawings,” on page
170. A
lso see Figure 3-33: “Dual Tank Electrical Harness Overview” on
page 88.

CAUTION !

BEFORE RUNNING WIRES FROM THE LOW TANK SWITCHES TO THE MAIN
CABLE HARNESS MAKE SURE THE WIRES FROM TANK “A” ARE IDENTI-
FIED AND PROPERLY LABELED.