Installer Installation

56

FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual

p/n: 029-0021-68-0

The ground strap should be a minimum of 1-1/4” (32mm) wide and no
longer than 18” (457mm). It must have soldered flat lug ends with 3/8”
(10mm) diameter holes.

If the ground strap length exceeds 18” (457mm), a wider ground strap
should be used or use a double thickness of 1-1/4” (32mm) wide ground
strap. The ground strap must be connected to the chassis. Use minimum
5/16” (8 mm) diameter bolt or mounting to secure the strap.

Make sure the ground is attached directly to the chassis frame and not to
the apparatus body work.

IMPORTANT !

BEFORE MAKING GROUND CONNECTIONS REMOVE ALL PAINT, GREASE
AND COATINGS FROM THE CONNECTION AREA. AFTER MAKING CONNEC-
TION, SEAL AGAINST CORROSION. WHEN A FLAT GROUND STRAP IS NOT
AVAILABLE USE A BATTERY CABLE ONE SIZE LARGER THAN THE POWER
CABLE USED.

FoamLogix Display

Power must be supplied to the FoamLogix display. The power required
should be a clean power supply and should only be provided after the pump
is placed in gear. Make display power and ground connections. Use mini-
mum 16 AWG Type SXL or GXL (SAE J1127) wire. Using the harness
provided:

Connect the BLACK wire to a chassis ground stud

Connect the

RED

wire to a minimum 5 AMP fused dedicated circuit. If a

dedicated circuit is not available, connect to a terminal that has LOW cur-
rent load items, such as ENFO IV, governor and tank level gauge, etc.

Foam Concentrate Tanks(s)

A foam concentrate tank(s) must be supplied to suit the capacity required
for the apparatus application. The tank(s) must meet NFPA minimum stan-
dards for their design capacity, including:

Filler size

Vapor pressure venting