FoamLogix 3.3 / 5.0 / 6.5 Installer / Operations Manual
p/n: 029-0021-68-0

Ope ra tion

While operating in any function, with the exception of FLOW during simu-
lated flow operation, whenever the or buttons are momentarily
pressed, the display switches to the % FOAM display and shows the current
injection rate for two (2) seconds.

In any display mode, if either the or button is held down for a period
of two (2) seconds or more, the injection rate value increases or decreases
accordingly. Once released, the display returns to the last selected display
after two (2) seconds.

When a RESET is performed while in the % FOAM mode, the foam concen-
trate injection rate returns to the default value.

5.5

FLUSH

Also see heading “Flushing Hale Foam-
Logix” on page 135. A
lso see Figure 5-
3: “Flush.”

If the Hale FoamLogix system is
equipped with an ADT, MDT II or MST
and the operating controls for these
selectors are in the FLUSH position, the
foam pump motor increases to approxi-
mately 80% capacity. The system oper-
ates for twenty (20) seconds when
water is flowing, then switches to the
STANDBY mode.

When in FLOW or TOTAL FLOW mode
the display alternates between FLUSH
and the value of the selected function. These modes function normally
when in FLUSH mode.

When in % FOAM or TOTAL FOAM mode, FLUSH is shown steady on the
display. These modes do not function while in FLUSH mode.

5.6

WARNING MESSAGES

Several safety features are incorporated into the Hale FoamLogix system to
protect the foam concentrate pump, electric motor and apparatus wiring
while maintaining personnel safety. These are described beginning on the
next page.

Figure 5-3: Flush