Object 0x6075: motor rate current, Object 0x6076: motor rate torque, 6076h: motor rated torque – ElmoMC CANopen DSP 402 Implementation Guide User Manual

Page 112

Advertising
background image

Object 0x6075: Motor Rate Current

This value is taken from the motor nameplate and is entered in multiples of milliamp.
Depending on the motor and drive technology this current may be either DC, peak or
rms (root-mean-square) current. All relative current data refers to this value.

Object description:

Index 6075h

Name

Motor Rate Current

Object code

VAR

Data type

UNSIGNED32

Category Mandatory

Entry description:

Access Read/write

PDO mapping

No

Value range

UNSIGNED32

Default value

0

Note: This value of 6075h is set to CL[1] after it is converted to Amperes.

Object 0x6076: Motor Rate Torque

This value is taken from the motor name plate and is entered as a multiple of mNm
(mill wtonmeter). All relative torque data refer to this value.
For linear motors, the object name is not changed, but the motor rated force value
must be entered as a multiple of mN (mill Newton)..

Object description:

Index 6076h

Name

Motor Rate Torque

Object code

VAR

Data type

UNSIGNED32

Category Mandatory

Entry description:

Access Read/write

PDO mapping

No

Value range

UNSIGNED32

Default value

0

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

106

Advertising