Object 0x605c: disable operation option code – ElmoMC CANopen DSP 402 Implementation Guide User Manual

Page 39

Advertising
background image

Data description:

Value Description

-32,768…-1 Manufacturer

specific

0

Disable drive function

1

Slow down on slow-down ramp; disable drive function

2…32,767 Reserved

An attempt to set an unsupported value causes the transmission of abort code

0609 0030, value exceeded.

ld be taken in case of the transition:

OPERATION ENABLE => SWITCHED ON.

Object description:

Index 605Ch

Object 0x605C: Disable operation option code
This parameter determines which action shou

Name

Disable operation option code

Object code

VAR

Data type

INTEGER16

Category Optional

Entry description:

Access Read/write

PDO mapping

No

Value range

INTEGER16

Default value

1

Data description:

Value Description

-32,768…-1 Manufacturer

specific

0

Disable drive function

1

Slow down on slow-down ramp and then disable drive function

2…32,767 Reserved

An attempt to set an unsupported value causes the transmission of abort

code 0609 0030: Value exceeded.

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

33