Object 0x6067: Position window
This object defines a symmetrical range of accepted positions relative to the target
position
. If the actual value of the position encoder is within the position window, this target
position
is regarded as reached. Because the position window is usually specified in user-
defined units, the position factor must be used to transform this value into increments.
Before it can be used with this function, the target position must be handled in the same
manner as in the trajectory generator for limiting functions and transformation into
internal machine units.

The Elmo drive always checks the target position window in its own setup

parameters TR[1] and TR[2] at the real-time level. Therefore, the following points
must be taken into account:

The position error mechanism cannot be switched off.

The limits of the position window and the position window time (in internal units)
are 32,000 increments and 100 milliseconds, respectively.

Object description:

Index 6067h

Name Position

window

Object code

VAR

Data type

UNSIGNED32

Category Optional

Entry description:

Access Read/write

PDO mapping

No

Value range

UNSIGNED32

Default value

No

Object 0x6068: Position window time
When the actual position is within the position window during the defined position window
time
— given in multiples of milliseconds — the corresponding bit 10 target reached in the
statusword is set to 1. Refer to the description in the position window object.

Object description:

Index 6068h
Name

Position window time

Object code

VAR

Data type

UNSIGNED16

Category Optional

CANopen DSP 402 Implementation Guide