5: Common Entries

5.1 Drive

Error

The drive functionality in case of an error is determined using the following objects:
6007h: defined according to the

SimplIQ

CANopen Implementation Manual.

603Fh: reflects the 16 lower bits of object 0x1003, which, together with this object, get the

emergency value regardless of the emergency message mask in object 2F21h.

Object 0x6007: Abort connection option code
This object details the motor control behavior after a heartbeat failure. It has no effect if
the motor is already off.

Object description:

Index 6007h
Name

Abort connection option code

Object code

VAR

Data type

INTEGER16

Category Optional

Entry description:

Access Read/Write
PDO mapping

No

Value range

-32,768…32,767

Default value

0

Data description:

(Command details are found in

SimplIQ

Command Reference Manual.)

Option
Code


Meaning


Details

0 No

action

1

Malfunction

Motor is off (MO=0) and motor failure code is
0x800. The failure is reported and possibly
activates an AUTOERR routine similar to
other failures (MF command).

2 Device

control

command
“Disable_voltage”

Motor is off (MO=0), but no failure indication
is set (MF=0).

3 Device

control

command “Quick_stop”

ST command is executed. Its action depends
on unit mode (UM).

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

12