Object 0x6083: Profile acceleration
The profile acceleration is given in user-defined acceleration units. It is converted to
position increments per second

2

using the normalizing factors.

Object description:

Index 6083h

Name Profile

acceleration

Object code

VAR

Data type

UNSIGNED32

Category Optional

Entry description:

Access Read/write

PDO mapping

No

Value range

UNSIGNED32

Default value

No

The value of the profile acceleration is reflected in the AC command, to which the

range and restrictions are ultimately submitted (refer to the

SimplIQ

Command

Reference Manual).

Object 0x6084: Profile deceleration
The profile deceleration is given in the same units as profile acceleration. If the end velocity
(object 0x6082) is different than 0, this object is not valid and the profiled deceleration is
considered to be similar to the profiled acceleration.

Object description:

Index 6084h

Name Profile

deceleration

Object code

VAR

Data type

UNSIGNED32

Category Optional

Entry description:

Access Read/write

PDO mapping

No

Value range

UNSIGNED32

Default value

No