Object 0x605b: shutdown option code – ElmoMC CANopen DSP 402 Implementation Guide User Manual

Page 38

Advertising
background image

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

32

Data description:

Value Description

-32,768…-1 Manufacturer

specific

0

Disable drive function

1

Slow down on slow-down ramp and then disable the drive

2

Slow down on quick-stop ramp and then disable the drive

3

Slow down on current limit and than disable the drive (tq
mode only)

4 Not

supported

5

Slow down on slow-down ramp and stay in QUICK STOP

7

Slow down on the current limit and stay in QUICK STOP
(tq mode only)

8 Not

supported

9…32,767 Reserved

An attempt to set an unsupported value causes the transmission of abort code

0609 0030: Value exceeded.

Object 0x605B: Shutdown option code
This parameter determines which action should be taken in case of the transition:
OPERATION ENABLE => READY TO SWITCH ON.

Object description:

Index 605Bh

Name

Shutdown option code

Object code

VAR

Data type

INTEGER16

Category Optional

Entry description:

Access Read/write

PDO mapping

No

Value range

INTEGER16

Default value

0