Object 0x605d: halt option code – ElmoMC CANopen DSP 402 Implementation Guide User Manual

Page 40

Advertising
background image

Object 0x605D: Halt option code
This parameter determines which action should be taken if bit 8 (halt) in the controlword
is active.

Object description:

Index 605Dh

Name

Halt option code

Object code

VAR

Data type

INTEGER16

Category Optional

Entry description:

Access Read/write

PDO mapping

No

Value range

INTEGER16

Default value

1

Data description:

Value Description

-32,768…-1 Manufacturer

specific

0

Disable drive function

1

Slow down on slow-down ramp

2

Slow down on quick-stop ramp

3

Slow down on current limit (only for tq mode)

3…32,767 Reserved

In Profile Position mode, the Halt option is not affected when this object is set.

CANopen DSP 402 Implementation Guide

MAN-CAN402IG (Ver. 1.2)

34

Advertising