4 electronic module - analog input, 1 "aix 12bit" and "aix 16bit" electronic modules, Aix 12bit" and "aix 16bit" electronic modules – Lenze L-force I/O System 1000 User Manual

Page 43: Electronic module - analog input ( 43), Electronic module - analog input, L-force controls | i/o system 1000

Advertising
background image

2.0 EN - 11/2010

L

43

L-force Controls | I/O System 1000

Parameter setting

Electronic module - analog input

6.4

Electronic module - analog input

6.4.1

"AIx 12Bit" and "AIx 16Bit" electronic modules

Use the Parameters tab to select the settings for the electronic module. In addition, the

channel status is indicated.

How to parameterise the electronic module:

1. Select the electronic module in the project view.
2. Click the Parameters tab in the workspace.

3. Make settings for each channel.

Legend

Description

Index

Accept module

parameter

Changed settings will not be accepted until the function has been executed.

Click the input field to open the drop down menu.

• 255: Accept module parameters

0x31FF

Channel status

Display of the current input signal of 0 ... 10 V.

0x6401

Signal function

Signal function of the channel.

Click the input field to open the drop down menu.

• 16: 0...10V /0...27648dec

–Voltage measurement of 0 ... 10 V and a resolution of 0 ... 27648.

–The value range is displayed in the object.

• 32: 0...10V /0...16384dec

–Voltage measurement of 0 ... 10 V and a resolution of 0 ... 16384.

–The value range is displayed in the object.

• 255: Channel deactivated

–No voltage measurement

0x31xx

Advertising