L-force controls | i/o system 1000, Networking via can system bus port assignment – Lenze L-force I/O System 1000 User Manual

Page 69

Advertising
background image

2.0 EN - 11/2010

L

69

L-force Controls | I/O System 1000

Networking via CAN system bus

Port assignment

EPM-S207

Channel status

Running number

Bit

Designation

Function

0

Channel status - DI1

0: FALSE

1: TRUE

1

Channel status - DI2

0: FALSE

1: TRUE

2 ... 7

Reserved

8 ... 15

Running number (RN)

Counter that starts counting from 0 … 127 and then restarts with 0.

EPM-S207

Ticker value

Bit

Designation

Function

0 ... 15

Ticker value

EPM-S310

Channel status

Running number

Bit

Designation

Function

0 ... 3

Reserved

4

Enabling DO2

0: Disabled

1: Enabled

5

Enabling DO1

0: Disabled

1: Enabled

6

Channel status - DO2

0: FALSE

1: TRUE

7

Channel status - DO1

0: FALSE

1: TRUE

8 ... 15

Running number (RN)

Counter that starts counting from 0 … 127 and then restarts with 0.

EPM-S310

FIFO memory status

Bit

Designation

Function

0 … 5

Running number of the TimeStamp entry last written to the FIFO

memory.

6

Reserved

7

Reserved

8 … 13

Running number of the TimeStamp entry that will be processed

next.

14

Reserved

15

Reserved

16 … 23

• 00

h

or 80

h

: OK

• 01

h

or 81

h

: No next entry

• 02

h

or 82

h

: No new entries available

• 03

h

or 83

h

: FIFO memory full. No new entries possible.

–When the memory is full, there will no more TimeStamp entries

be accepted. Check the FIFO memory status before transmitting

further TimeStamp entries.

24 … 31

Number of TimeStamp entries in the FIFO memory.