6.7.2
Operating mode
Master mode
In the master mode, the module is directly connected to an SSI encoder which it also
supplies. To evaluate the encoder, the module issues clock pulses to the encoder and
provides the received data in the form of a process image.
[6.9]
Block diagram: Master mode