L-force Controls | I/O System 1000

Parameter setting

Electronic modules - counters

56

L

2.0 EN - 11/2010

6.6.9

Periodic counting: Main counting direction - counting down

Function:

The counter starts counting down from the start value.

If the counter reaches the final value +1 in the negative direction, it jumps to the start

value with the next negative count pulse and continues counting from there.

The counter is able to continue counting above the upper counting limit value.

[6.8]

Example of "Periodic counting", main counting direction - counting down

Limits

Counting range

Final value

-2 147 483 646 (-2

31

+1) … +2 147 483 646 (-2

31

-1)

Upper counting limit +2 147 483 646 (-2

31

-1)