Parameter setting

Electronic modules - counters

6.6.6

Counting only once: Main counting direction - counting down

Function:

The counter starts counting down from the start value.

If the counter reaches the final value +1 in the negative direction, it jumps to the start

value with the next count pulse and the counter will stop automatically.

After a restart, the counter starts counting from the start value.

The counter is able to continue counting above the upper counting limit value.

[6.5]

Example of "Counting only once" with main counting direction - counting down

Limits

Counting range

Final value

-2 147 483 646 (-2

31

+1) … +2 147 483 646 (-2

31

-1)

Upper counting limit +2 147 483 646 (-2

31

-1)