Chapter 5

Functional Description

5-36

Figure 5.5 (Sheet 3 of 3) 1395 Block Diagram

9

CURRENT REFERENCE CONTROL

FLUX COMMAND

FIELD

ECONOMY

DELAY

ARMATURE

CURRENT REF

SCALING

Torque Command 110

4096 = 100%

Rated Torque

From

Sheet 1

4096 = 1PU TORQUE

DRIVE STOPPED

FLUX

TORQUE TAPER

%

FLUX

COMPENSATION

%

TORQUE

DISABLE DIVIDE

BY FLUX

FLUX MODE SELECT

627

7

11

FIELD FLUX CONTROL

4

CEMF

121

CEMF

PI CONTROL

PI

672 KI FLUX/3277

673 KP FLUX/4096

687 CEMF PRELOAD

FLUX MODE

SELECT

627

ARM CURRENT

REF

111

FIELD

WEAKENING

SELECT

410

(10% FLUX)

AUTO

TUNE

GAIN

4096 = 1 PU FLUX

RPM

RPM

%

%

Fwd Brdg Cur Lim

663

Min Taper Cur Lim

667

Rev Brdg Cur Lim

664

Strt Taper Spd

665

End Taper Spd

666

I LIMIT

SPD

FWD I

LIMIT

REV I

LIMIT

DI/DT

LIMIT

%

DI/DT LIMIT

668

AMPS

AMP

611

MOTOR ARM FLA

AMP

615

RATED ARM BRDG I

G

+

ARMATURE

CURRENT

FEEDBACK

0 I = T

FWD TORQUE

LIMIT

C

REV TORQUE

LIMIT

To

Sheet 2

To

Sheet 2

B

D

1 PU

FLUX

SEC

FLD ECON

DLY 675

STOPPED = 1

FIELD

ECONOMY

SELECT

FLUX MODE SELECT

627

0

Fld Econ Ref 674

%

FLUX COMMAND

Fld Flux Ref 676

%

FLUX

MODE

SELECT

627

1

Fdbk Device Type 621

+

FLUX

FLUX FEED

FORWARD SELECT

2

5

+

FLUX MODE

SELECT

627

%

12

FIELD WEAKENING CONTROL

FLUX FEED FWD 159

CEMF

SPEED

FLUX

CALC

CEMF

SPEED

FLUX

CALC

FLUX

ERROR

ERROR

+

CEMF

REFERENCE

SELECT

%

3

FLUX MODE

SELECT

627

4096

CEMF REF

MAX

RPM

686

P686 = Field Weaken Speed

4096 = Base

Mtr RPM

MAX

4096

ABS

ABS

From

Sheet 2

RPM

VELOCITY

FDBK

106

A

From

Sheet 2

CEMF

FDBK

CEMF

FDBK

MOTOR FLA

BRIDGE FLASPX4

CEMF HOLD

TRIM

BYPASS INTEGRATOR

WHEN ON LIMIT

160

CEMF REF

4096 = 1PU

CEMF

F

R

M

M

= 1

≠ 1

1

No Flux Comp

Bit 1 = Field Weaken Enable

Bit 0 = Field Economy Enable

Bit 2 = Ext Feed Forward Enable

CEMF Control Enable

CEMF RESET