Rockwell Automation 1395 Digital DC Drive FRN 5-10.10/9.30 User Manual

Page 177

Advertising
background image

Chapter 7
Programming Parameters

7-11

Table 7.A Cont.

PARM

625

626

627

628

629

630

631

632

633

UNITS

*

RPM

RPM

RPM

RPM

RPM

RPM

RPM

SEC

SEC

SEC

SEC

SEC

SEC

SEC

SEC

RPM

RPM

SEC

SEC

%

%

%

%

%

RPM

RPM

%

%

%

NAME

Torque Mode

Jog Ramp Enable

Flux Mode Select

Proc Trim Select

MTR Overload Sel

Fault Report

Vel Filter Sel

Warning Select

Preset Speed 1

Preset Speed 2

Preset Speed 3

Preset Speed 4

Preset Speed 5

Jog Speed 1

Jog Speed 2

MOP Accel 1

MOP Accel 2

MOP Accel 3

MOP Accel 4

MOP Decel 1

MOP Decel 2

MOP Decel 3

MOP Decel 4

MOP Max Speed

MOP Min Speed

Accel Time

Decel Time

Desired Contour

Droop Percent

Droop Filter

KI Velocity Loop

KP Velocity Loop

KF Velocity Loop

Fwd Brdg Cur Lim

Rev Brdg Cur Lim

Strt Taper Speed

End Taper Speed

Min Taper Current

DI/DT Limit

Slave Percent

MIN

0

0

0

0

0

0

–6xB.S.

–6xB.S.

–6xB.S.

–6xB.S.

–6xB.S.

–6xB.S.

–6xB.S.

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0

0

0.1

0.1

0

0

0

0

0

0

0.0244

0.0244

B.S./4096

B.S./4096

0.0244

0.0244

–200

MAX

5

1

2

4

1

2

+6xB.S.

+6xB.S.

+6xB.S.

+6xB.S.

+6xB.S.

+6xB.S.

+6xB.S.

6553.5

6553.5

6553.5

6553.5

6553.5

6553.5

6553.5

6553.5

+6xB.S.

+6xB.S.

6553.5

6553.5

100

25.5

100%

32767

1600

65535

260

260

+6xB.S.

+6xB.S.

260

260

200

FUNCTION/CLASSIFICATION/PORT

Torque Select

Ramp Cntrl/Set-Up

Field Flux Control/Set-Up

Process Trim Control/Set-Up

Fault Detection/Setup

Fault Detection/Set-Up

Velocity Ref Cntrl/Setup

Fault Detection/Setup

Velocity Ref Cntrl/Spd Ref

Velocity Ref Cntrl/Spd Ref

Velocity Ref Cntrl/Spd Ref

Velocity Ref Cntrl/Spd Ref

Velocity Ref Cntrl/Spd Ref

Velocity Ref Cntrl/Spd Ref

Velocity Ref Cntrl/Spd Ref

MOP Control

MOP Control

MOP Control

MOP Control

MOP Control

MOP Control

MOP Control

MOP Control

MOP Control

MOP Control

Ramp Control

Ramp Control

Ramp Control

Droop Control/Set-Up

Droop Control/Set-Up

Velocity PI Control/Autotune

Velocity PI Control/Autotune

Velocity PI Control/Autotune

Current Ref Control

Current Ref Control

Current Ref Control/Set-Up

Current Ref Control/Set-Up

Current Ref Control/Set-Up

Current Ref Control/Set-Up

Torque Control/Set-Up

HEX

271H

272H

273H

274H

275H

276H

277H

278H

279H

INIT

1

0

*

0

1

1

0

0

0

0

0

0

0

0

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

1750

0

10

10

0

0

0

256

64

65535

50%

50%

B.S.

B.S.

100

25.0%

100

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

634

635

636

637

638

639

641

642

643

644

645

646

647

648

649

650

651

652

653

657

658

659

660

661

663

664

665

666

667

668

669

27AH

27BH

27CH

27DH

27EH

27FH

281H

282H

283H

284H

285H

286H

287H

288H

289H

28AH

28BH

28CH

28DH

291H

292H

293H

294H

295H

297H

298H

299H

29AH

29BH

29CH

29DH

Advertising