Parameter 630 – Fault Report [Fault Report]

Internal units : None

Programming Terminal units: None

Minimum Value: 0

Maximum Value: 1

Default Value: 1

Description: This parameter selects whether Velocity or Current

Control fault status will be written to the FAULT WORD (Parameter

101).

0 = Select Current Processor Faults

1 = Select Velocity Processor Faults

P

arameter 631 – Velocity Feedback Filter Select [Vel Filter Selct]

Internal units : None

Programming Terminal units: None

Minimum Value: 0

Maximum Value: 2

Default Value: 0

Description: This parameter selects a 2 pole feedback filter or a

lead/lag velocity feedback filter. When option 3 is selected,

Parameters 692 “KN Filter” and Parameter 693 “Wn Filter” must be

configured. One of four selections can be made as follows:

0 = No filter

1 = 35/49 radian filter

2 = 20/40 radian filter

3 = Lead/Lag velocity filter

Parameter 632 – Warning Select [WARNING SELECT]

Internal units : None

Programming Terminal units: Bit field

Minimum Value: All bits off

Maximum Value: All bits on

Default Value: 0

Description: This parameter can enable/disable certain warning fault

detection. If set to a 1, that particular fault will not be reported in the

fault word (Parameter 101), or in the fault queue. If set to 0, the fault

will be detected and reported as usual. The following bits define the

fault:

Bit 0 – Motor overload pending

Bit 1 – Excessive Armature volts demand

Bit 2 – Bridge overload pending

Parameter 633 – Preset Speed 1 [Preset Speed 1]

Programming Terminal units: RPM

Minimum Value: – 6 x base speed

Maximum Value: +6 x base speed

Default Value: 0

Description: This will be the velocity reference used by the drive

when preset 1 has been selected in the logic command word.