Chapter 5
Functional Description

5-10

Table 5.B
Control Logic Source Parameters

Number

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

Name

Logic Status

Drive Fault

Pre Ramp Vel Ref

Ramp Vel Ref

Final Vel Ref

Arm Voltage Fdbk

Velocity Fdbk

Position Fdbk

Vel Feed Fwd

Position Error

Torque Command

Arm Current Ref

Arm Current Fdbk

Arm Cur PI Out

Arm Cur Fire Ang

Flux Command

AC Line Voltage

Fld Current Ref

Fld Current Fdbk

Proc Trim Output

Function

16 bit word used to indicate the present operating condition of
the drive.

16 bit word used to indicate fault conditions in the drive.

Velocity reference output from the Velocity Reference Control

Velocity reference output from the Ramp Control.

Velocity Reference input to the Velocity PI Control which is the
sum of the output from the Ramp Control, Process Trim and
Droop functions.

Actual armature voltage.

Final velocity feedback used as input to the Velocity PI
Control.

Final position feedback used as input to the position control
portion of the Velocity PI Control

Error term used in proportional path of the velocity PI regulator

Error between position reference and position feedback
(P107)

Internal Torque Reference

Torque command scaled by flux command.

Actual armature current.

Output of the Armature Current PI Control

P113 converted to an angle reference modified by
discontinuous current adaptation when operating in
discontinuous current range.

Output of the field flux control.

Actual three-phase input line voltage.

Flux command scaled by the Field Flux Linearization Table.

Actual field current.

Output of velocity trim control.

Linking Source to Sink Parameters

In order for information from a Source parameter to be input to a Sink
parameter, a link must be made between the two desired parameters. For
example, to send the information from Parameter 400 (first Source
parameter associated with Port A) to Parameter 151 (pre-defined as Logic
Cmd 2, input), then Parameter 151 must be linked to Parameter 400.
Linking of Parameter 151 to 400 is shown in Figure 5.3.

Linking of parameters is accomplished using the drive Setup Mode on the
Programming Terminal. The drive will allow a total of 20 links to be
made. There are two fixed links that cannot be altered or reconfigured,
thereby allowing a maximum of 18 user configurable links. Linking of
Sources to Sinks is referred to as “Configuring” the drive. For a complete
description of how to use the Programming Terminal to configure the
drive, refer to the Programming Terminal Instruction Manual. It should be