Specifications

Input Voltages –

Input Power –

Input Frequency –

Max Rate of Change of

Input Frequency –

Output Voltage –

Output Horsepower

(Continuous) –

Output Current–

Field Voltage–

Field Current–

Field Control–

Field Economy–

Armature Firing–

Output Waveform–

Controller Current

Output –

Armature Control –

150 – 460VAC +/– 10%, 3 phase

115VAC Control Power, +/– 10%, 1 phase
1.5 kVA to 660 kVA

50/60Hz +/– 3 Hz.

3.5 Hz/Sec.

240VDC (230VAC Input)

400VDC (380 – 415 AC Input)

500VDC (460VAC Input)

1 to 300 HP, 240VDC

1.5 to 500 HP, 400VDC

2 to 600 HP, 500VDC

3.6 to 980A

120 – 150VDC, 230VAC

200 – 250VDC, 380VAC

220 – 270VDC, 415VAC

240 – 300VDC, 460VAC

Field Voltage Source is selectable between

internal or external supply.

1 – 30HP, 230V; 2 – 60HP, 460V Drive:

150mA – 10 Amperes Continuous

40 – 100HP, 230V; 75 – 200HP, 460V

Drive: 650mA – 20 Amperes (continuous)

125 – 300HP, 230V; 250 – 600HP, 460V

Drive: 650mA – 40 Amperes (continuous)

A 6:1 speed range with an encoder or DC

tach feedback

Programmable enable, time delay, power on

standby

Phase sequence insensitive, Regenerative/

Non–regenerative

6 pulse, full wave, NEMA Code C

150% for one minute, 200% for 10 seconds,

260% for 5 seconds

Tapered current limit, di/dt limit, Instanta-

neous overcurrent, Programmable motor

overload

Speed Regulation:

Encoder –

DC Tachometer –

Armature Voltage –

0.01% of set speed (over a 10:1 speed

range); 0.001% of top speed (over a 100:1

speed range).
0.5% of top speed with 5PY tachometer;

0.1% of top speed with BC42 tachometer.

2% of top speed

Electrical:

Type Drive:

Full Wave Regen, 12 SCR w/Full Wave 1

∅ Field Regulator