Rockwell Automation 1395 Digital DC Drive FRN 5-10.10/9.30 User Manual

Page 15

Advertising
background image

Chapter 1
Introduction, Inspection & Storage, and
Publication References

1-5

Enable/Contingency
Coast Stop –
System Reset –
Motor Thermostat –
Communication Port –

24VDC/115VAC, hard–wired to DC
contactor
24VDC/115VAC, Isolated
24VDC/115VAC, Isolated
RS–422 for programming terminal

External Inputs:

Drive Ready/Faulted–

N.O. relay contact, open when drive faulted
or de–energized, closed when ready. Con-
tact rating – 1 ADC @ 24 VDC or 0.5A @
120VAC

External Outputs:

Ambient Operating
Temperature
Relative Humidity
Altitude

0

°

to 55

°

C (32

°

– 130

°

F)

5% to 95%, non–condensing
3,300 feet (1,000 meters)

Environmental

Accel/Decel

Preset Speeds
Jog Speeds
“S” Ramp
Motor Operated Pot
(MOP)

0.1 to 6554 seconds, independently
programmable.
5 adjustments, programmable
2 adjustments, programmable
Programmable
10 adjustments, programmable

Standard Features

Discrete Adapter
Board;

Digital Inputs (4) –

Digital Outputs (2) –

Analog Inputs (4) –

Analog Outputs (4) –

Power Supply (For
external use) –

24VDC or 120VAC, 10 mA. NOTE: A
separate board and part number is used for
each voltage rating.

Dry relay contacts rated at 0.6 amps at
125VAC or 2.0 amps at 30VDC.

0 to +/– 10 VDC, differential input imped-
ance – 20K ohms.

–10 to + 10VDC, 1mA minimum output
impedance – 200 ohms.

+10VDC, 4mA maximum, –10VDC,
4mA maximum.

Options

Incremental, dual channel; 12 volts,
500mA, isolated with differential transmit-
ter, 102.5 kHz max. Quadrature : 90

° ±

27

°

@ 25

°

C, Duty Cycle: 50%

±

10% Source/

Sink capable, A–B 845H or equal.

Feedback Devices:

Encoder –

DC Tachometer –

5 PY, BC42 or equal