Appendix

B

Module Parameters

Appendix B provides information about the EtherNet/IP-to-SCANport
module parameters.

The parameters in the module are numbered consecutively. However,
depending on which configuration tool you use, they may have different
numbers.

Topic

Page

About Parameter Numbers

B-1

Parameter List

B-1

About Parameter Numbers

Configuration Tool

Numbering Scheme

• DriveExplorer

• DriveExecutive

The module parameters begin with parameter 01. For
example, Parameter 01 - [SCANport Adapter] is
parameter 01 as indicated by this manual.

• Explicit Messaging

Refer to

Chapter 6

,

Using Explicit Messaging

, and

Appendix C

,

EtherNet/IP Objects

, for details.

Parameter List

Parameter
No. Name and Description

Details

01

[SCANport Adapter]
Displays the port to which the module is
connected.

Default:

7

Minimum:

0

Maximum:

7

Type:

Read Only

02

[BOOTP]
Configures the module to use BOOTP so that you
can set its IP address, subnet mask, and gateway
address with a BOOTP server.

Default:

1 = Enabled

Values:

0 = Disabled
1 = Enabled

Type:

Read/Write

Reset Required:

Yes