Scanport parameter object, Class code, Instances – Rockwell Automation 1203-EN1 EtherNet/IP-to-SCANport Module User Manual

Page 130: Class attributes, C-20 c-20, C-20, Class code instances

Advertising
background image

C-20

EtherNet/IP Objects

Class Code

Instances

The number of instances depends on the number of parameters in the
device. The total number of parameters can be read in Instance 0,
Attribute 0.

Class Attributes

SCANport Parameter Object

Hexadecimal

Decimal

0x93

147

Instances (Hex.) (Dec.)

Device

Example Description

0x0000 – 0x3FFF 0 – 16383

Host

0

Class Attributes (Drive)

0x4000 – 0x43FF 16384 – 17407 Module

1

Drive Parameter 1 Attributes

2

Drive Parameter 2 Attributes

16384

Class Attributes (Module)

16385

Module Parameter 1 Attributes

Attribute
ID

Access
Rule

Name

Data Type Description

0

Get

Number of
Instances

WORD

Number of parameters in the device

1

Set

Write Protect
Password

WORD

0 = Password disabled
n = Password

2

Set

NVS Command
Write

BYTE

0 = No Operation
1 = Store values in active memory to NVS
2 = Load values in NVS to active memory
3 = Load default values to active memory

3

Get

NVS Parameter
Value Checksum

WORD

Checksum of all parameter values in a
user set in NVS

Advertising