Setting web features access, Setting web features access -15 – Rockwell Automation 1203-EN1 EtherNet/IP-to-SCANport Module User Manual

Page 41

Advertising
background image

Configuring the Module

3-15

By accessing the IP address set for the module using a web browser, you
can view the module’s web pages for information about the module and
the drive to which it is connected. Additionally, the module can be
configured to automatically send e-mail messages to desired addresses
when selected drive faults occur and/or are cleared, and/or when the
module takes a communication or idle fault action. For more details on
the module’s web pages, refer to

Chapter 8

,

Viewing the Module’s Web

Pages

.

By default, the module web pages are disabled.

To enable the module web pages

• Refer to

Figure 2.1

and set the Web Pages Switch (SW2) to the

“Enable Web” (down) position.

Important: For a change to the switch setting to take effect, the

module must be reset (see

Resetting the Module

section

in this chapter).

Bit 0 of Parameter 65 - [Web Features] is used to protect the
configured settings for e-mail notification. By default, settings are not
protected. To protect an e-mail configuration, set the value of E-mail Cfg
Bit 0 to “0” (Disabled). You can unprotect the configuration by changing
Bit 0 back to “1” (Enabled). E-mail notification will always remain
active regardless of whether or not its settings are protected — unless
e-mail notification was never configured. For more information about
configuring module e-mail notification or stopping e-mail messages,
refer to

Chapter 8

,

Configure E-mail Notification Web Page

).

Changes to this parameter take effect immediately. A reset is not required.

Setting Web Features Access

Table 3.O Parameter 65 - [Web Features] Bit Assignments

Bit

Description

0 (right-most bit)

E-mail Cfg (Default = 1 = Enabled)

1 - 7

Not Used