Scanport warning object, Class code, Instances – Rockwell Automation 1203-EN1 EtherNet/IP-to-SCANport Module User Manual
Page 135: Class attributes, C-25
EtherNet/IP Objects
C-25
Class Code
Products such as drives use this object for alarms or warnings. Modules
do not support this object.
Instances
The number of instances depends on the maximum number of warnings
supported by the queue. The maximum number of warnings can be read
in Instance 0, Attribute 1.
Class Attributes
SCANport Warning Object
Hexadecimal
Decimal
0x98
152
Instances (Hex.) (Dec.)
Device
Example Description
0x0000 – 0x3FFF 0 – 16383 Host
0
Class Attributes (Drive)
Only host devices can have warnings.
1
Most Recent Warning
2
Second Most Recent Warning
…
…
Attribute
ID
Access
Rule
Name
Data Type
Description
0
Set
Warning
Command Write
BYTE
0 = No Operation
1 = Clear Warning
2 = Clear Warning Queue
3 = Reset Device
1
Get
Number of
Instances
WORD
Maximum number of warnings that
the device can record in its queue