Module Parameters

B-7

46

[M-S Output]
Sets the Master-Slave output data. This data is
produced by the module and consumed by the
scanner.

Default:

xxx0 0001

Bit Values:

0 = I/O disabled
1 = I/O enabled

Type:

Read/Write

Reset Required:

Yes

Bit Definitions
0 = Status/Fdbk
1 = Datalink A Output
2 = Datalink B Output
3 = Datalink C Output
4 = Datalink D Output
5 = Not Used
6 = Not Used
7 = Not Used

47

[Ref Adjust]
Sets the percent scale factor for the Reference
from the network.

Default:

100.00

Minimum:

0.00

Maximum:

200.00

Type:

Read/Write

Reset Required:

No

48
49

[Peer A Input]
[Peer B Input]
Configures the destination in the drive of the Peer
I/O input. The module receives this data from the
network and sends it to the drive.

Important: Changes to these parameters are
ignored when Parameter 57 - [Peer Inp Enable] is
On.

Important: If the parameter is set to input a Logic
Command, configure the mask in Parameter 50 -
[Peer Cmd Mask] so that the desired bits from the
Peer device are used.

Default:

0 = Off

Values:

0 = Off
1 = Cmd/Ref
2 = Datalink A Input
3 = Datalink B Input
4 = Datalink C Input
5 = Datalink D Input

Type:

Read/Write

Reset Required:

No

50

[Peer Cmd Mask]
Configures the mask for the Logic Command word
when it is received through peer input. If the mask
bit is 0 (Off), the command bit is ignored and not
used. If the mask bit is 1 (On), the command bit is
checked and used.

Default:

0000 0000 0000 0000

Minimum:

0000 0000 0000 0000

Maximum:

1111 1111 1111 1111

Values:

0 = Ignore bit
1 = Use bit

Type:

Read/Write

Reset Required:

Yes

Parameter
No. Name and Description

Details

Bit

Default

1

0

0

0

0

x x

x

0

1

2

3

4

5

7 6

!

ATTENTION: To guard against equipment damage and/or personal injury, note
that changes to Parameter 47 - [Ref Adjust] take effect immediately. A drive
receiving its Reference from the module will receive the newly scaled Reference,
resulting in a change of speed.

!

ATTENTION: If the module receives a Logic Command from both a Master device
and a Peer device, each command bit must have only one source. This includes
the stop bit. The source of command bits set to “0” will be the Master device. The
source of command bits set to “1” will be the Peer device.