Page 104: Velocity preset 2, Velocity preset 3, Velocity preset 4, Velocity preset 5, Velocity preset 6, Velocity preset 7, Limit preset accel

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

2-88

Programming Reference

279

Set

Motor Gear
Count 7

INT

2

Cnts

Motor encoder counts for preset gear ratio 7. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1

280

281

282

283

284

285

286

287

Set

Velocity Preset 0

Velocity Preset 1

Velocity Preset 2

Velocity Preset 3

Velocity Preset 4

Velocity Preset 5

Velocity Preset 6

Velocity Preset 7

DINT

4

Cnts /
Sec

If the drive is in Velocity Preset mode, then Preset
Select Lines 0, 1, and 2 will select the Preset
Velocity parameter used for the velocity command.
Range: -0x7fffffff to 0x7fffffff
Default: 0

288

Set

Limit Preset
Accel

USINT

1

Indicates if the analog acceleration limits are
enabled or disabled when the drive is in Preset
Velocity Input mode
0 - Disable
1 - Enable (default)

289

Set

Preset Accel
Limit

UDINT

4

Cnts /
Sec

2

The acceleration limit used when the drive is in
Preset Velocity Input mode and Parameter 288, Limit
Preset Accel
is set to 1 - Enable (default).
Range: 0 to 0x7fffffff
Default: 100000

290

Set

Preset Decel
Limit

UDINT

4

Cnts /
Sec

2

The deceleration limit used when the drive is in
Preset Velocity Input mode and Parameter 288, Limit
Preset Accel
is set to 1 - Enable (default).
Range: 0 to 0x7fffffff
Default: 100000

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description

Advertising