30

Set

Current Setpoint

INT

2

Amps /
128

The current command value used when Parameter
28 - Host Control Mode is set to 2 - Setpoint Current.
The Current Setpoint setting is not saved in
nonvolatile memory.
Range: -32767 to 32767
Default: 0

31

Set

Setpoint Accel

UDINT

4

Cnts /
Sec

2

The maximum rate of acceleration (or deceleration)
the drive will use to ramp up (or down) when the
drive is in Setpoint Velocity mode and the Velocity
Setpoint is changed.
Range: 0 to 0x7fffffff
Default: 100000

32

Set

Motor Forward
Direction

USINT

1

Determines the positive motor direction.
0 - Normal (default) - A positive direction move
increases the encoder count.
1 - Reverse - A positive direction move decreases
the encoder count.

Note: Set is not allowed if the drive is enabled.

33

Set

Operation Mode

USINT

1

The drive's command source and operating mode.
0 - Analog Velocity Input (default)
1 - Analog Current Input
2 - Preset Velocity
3 - Preset Current
4 - Follower: Auxiliary Encoder
5 - Follower: Step / Direction
6 - Follower: Step Up / Step Down
7 - Indexing (Indexing Drive only)
8 - Analog Position (Indexing Drive only)
9 - Preset Position (Indexing Drive only)

Note: Set is not allowed if the drive is enabled.

34

Set

Override Mode

USINT

1

The drive's command source and operating mode
used when the Operation Mode Override input is
active.
0 - Analog Velocity Input (default)
1 - Analog Current Input
2 - Preset Velocity
3 - Preset Current
4 - Follower: Auxiliary Encoder
5 - Follower: Step / Direction
6 - Follower: Step Up / Step Down
7 - Indexing (Indexing Drive only)
8 - Analog Position (Indexing Drive only)
9 - Preset Position (Indexing Drive only)

Note: Set is not allowed if the drive is enabled.

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description