Reset faults, Reset drive, Reset personality – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 71

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-55

19

Set

Broadcast
Address

USINT

1

The address used by a host PC to issue a single
broadcast command to all connected Ultra3000
drives. The drive does not send a response to
commands received with the broadcast address. If
the Broadcast Address is modified, then the drive
must be reset for the drive to use the new address.

Note: If a drive's Broadcast Address and Serial
Address are set to the same value, the drive will
treat all serial commands as normal, point-to-point
commands, and will send a response to all
commands it processes.
Range: 0 to 255
Default: 255

20

Set

Serial Baud Rate

USINT

1

The baud rate for the drive's serial communications
port. If the baud rate is modified, then the drive must
be reset for the drive to use the new baud rate.
0 - 1200
1 - 2400
2 - 4800
3 - 9600
4 - 19200
5 - 38400 (default)

21

Set

Frame Format

USINT

1

The packet frame format for the drive's serial
communications port. If the frame format is
modified, then the drive must be reset for the drive
to use the new frame format.
0 - 7 Data Bits, Even Parity, 1 Stop Bit
1 - 7 Data Bits, Odd Parity, 1 Stop Bit
2 - 8 Data Bits, No Parity, 1 Stop Bit (default)
3 - 8 Data Bits, Even Parity, 1 Stop Bit
4 - 8 Data Bits, Odd Parity, 1 Stop Bit

22

Set

Reset Faults

USINT

1

Resets any drive faults. Motion may occur after
clearing drive faults if the drive is enabled.
0 - No Action (default)
1 - Reset

23

Set

Reset Drive

USINT

1

Resets, or reboots, the hardware and firmware in the
drive.
0 - No Action (default)
1 - Reset

Note: Set is not allowed if the drive is enabled.

24

Set

Reset Personality USINT

1

Resets the drive's parameters by reinitializing them
to factory default settings. Stored faults in the fault
history remain unchanged.
0 - No Action (default)
1 - Reset

Note: The drive is reset after the parameters are
reinitialized.

Note: Set is not allowed if the drive is enabled.

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description