Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 83

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-67

90

Set

Digital Output 1
Configuration

DWORD

4

Each digital output configuration parameter assigns
one or more functions to the corresponding Digital
Output (or Relay Output). Selecting a function will
cause the Digital Output to become active when the
associated function becomes active. If no functions
are selected by a digital output configuration
parameter, then the corresponding Digital Output (or
Relay Output) is unassigned.

Bit 0 = At Home
Bit 1 = End of Sequence
Bit 2 = In Motion
Bit 3 = In Dwell
Bit 4 = Registered
Bit 5 = Axis Homed
Bit 6 = Tracking
Bit 7 = Startup Commutation Done
Bit 8 = Positive Hardware Overtravel
(Motor Integral Limit)
Bit 9 = Negative Hardware Overtravel
(Motor Integral Limit)
Bit 10 = Positive Overtravel
Bit 11 = Negative Overtravel
Bit 12 = At Index 0 Position
Bit 13 = At Index 1 Position
Bit 14 = Position Compare 1
Bit 15 = Position Compare 2
Bit 16 = In Position
Bit 17 = Within Position Window
Bit 18 = Zero Speed
Bit 19 = Within Speed Window
Bit 20 = Positive Current Limit
Bit 21 = Negative Current Limit
Bit 22 = Up to Speed
Bit 23 = Drive Enabled
Bit 24 = DC Bus Charged
Bit 25 = Fault Disable
Bit 26 = Reserved
Bit 27 = Reserved
Bit 28 = Reserved
Bit 29 = Reserved
Bit 30 = Brake
Bit 31 = Ready

Default = 0x00000000

Note: Set is not allowed if the drive is enabled.

91

Set

Digital Output 2
Configuration

DWORD

4

92

Set

Digital Output 3
Configuration

DWORD

4

93

Set

Digital Output 4
Configuration

DWORD

4

94

Set

Relay Output
Configuration

DWORD

4

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description

Advertising