Position compare 1 type, Position compare 1 min, Position compare 2 type – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 77: Position compare 2 min, R 49 (position compare 1 type), p, Ter 50 (position compare 1 min), R 51 (position compare 2 type), p, Ter 52 (position compare 2 min)

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

Programming Reference

2-61

49

Set

Position Compare

1 Type

USINT

1

Selects the type of comparison that will determine if
the Position Compare 1 flag should be set.
0 - Greater Than (default) - The flag will be set if the
motor feedback position is greater than the
Position Compare 1 Min value.
1 - Less Than - The flag will be set if the motor
feedback position is less than the
Position Compare 1 Min value.
2 - Within Window - The flag will be set if the motor
feedback position is greater than
Position Compare 1 Min and less than Parameter
112 - Position Compare 1 Max.
3 - Outside Window - The flag will be set if the
motor feedback position is less than
Position Compare 1 Min or more than Position
Compare 1 Max
.

Note: The Position Compare 1 Type does not operate
unless the drive was previously homed.

50

Set

Position Compare

1 Min

DINT

4

Cnts

The position that will be compared to the motor
(auxiliary) feedback position to determine if the
Position Compare 1 flag should be set.
Range: -0x7fffffff to 0x7fffffff
Default: 0

51

Set

Position Compare

2 Type

USINT

1

Selects the type of comparison that will determine if
the Position Compare 2 flag should be set.
0 - Greater Than (default) - The flag will be set if the
motor feedback position is greater than the
Position Compare 2 Min value.
1 - Less Than - The flag will be set if the motor
feedback position is less than the
Position Compare 2 Min value.
2 - Within Window - The flag will be set if the motor
feedback position is greater than
Position Compare 2 Min and Less than Parameter
113 - Position Compare 2 Max.
3 - Outside Window - The flag will be set if the
motor feedback position is less than
Position Compare 2 Min or more than Position
Compare 2 Max
.

Note: The Position Compare 2 Type does not operate
unless the drive was previously homed.

52

Set

Position Compare

2 Min

DINT

4

Cnts

The position that will be compared to the motor
(auxiliary) feedback position to determine if the
Position Compare 2 flag should be set.
Range: -0x7fffffff to 0x7fffffff
Default: 0

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description

Advertising