38

Set

Negative I Limit

USINT

1

%

The negative current limit value. The value is a
percentage of the lesser of the intermittent (peak)
drive current rating and intermittent (peak) motor
current rating. During runtime, the drive limits
positive current to the lesser of the:

• Negative Current Limit,
• Analog Current Limit input,
• Intermittent Current rating of the drive, or
• Intermittent Current rating of the motor.
Range: 0 to 100
Default: 100

39

Set

Soft Overtravel

USINT

1

Enables or disables the software overtravel limit
checking.
0 - Disable (default)
1 - Enable

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

Note: The Soft Overtravel does not operate unless
the drive was previously homed.

40

Set

Positive Soft
Position Limit

DINT

4

Cnts

The absolute position that will cause a deceleration
to zero velocity when exceeded in the positive
direction.
Range: -0x7fffffff to 0x7fffffff
Default: 0x7fffffff

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

Note: The Positive Soft Position Limit does not
operate unless the drive was previously homed.

41

Set

Negative Soft
Position Limit

DINT

4

Cnts

The absolute positive that will cause a deceleration
to zero velocity when exceeded in the negative
direction.
Range: -0x7fffffff to 0x7fffffff
Default: -0x7fffffff (0x80000001)

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

Note: The Negative Soft Position Limit does not
operate unless the drive was previously homed.

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description

Advertising