Publication 2098-RM004A-EN-P – August 2002

2-80

Programming Reference

194

Set

Motor Flag

USINT

1

Indicates if the drive is configured for a standard or
custom motor. The pre-configured motor database in
Ultraware supplies parameters for standard motors.
The drive does not use this parameter for
configuration via Parameter Object Set.
0 - Custom Motor (default)
1 - Standard Motor

Note: Set is not allowed if the drive is enabled.

195

Set

Motor Type

USINT

1

The type of motor connected to the drive.
0 - Rotary Motor (default)
1 - Linear Motor

Note: Set is not allowed if the drive is enabled.

196

Set

Torque Constant
Kt

UINT

2

N-m/A
/ 4096

The torque constant for a rotary motor
(Active if Parameter Instance 195 = 0).
Range: 1 to 65535
Default: 2458

Note: Set is not allowed if the drive is enabled.

197

Set

Force Constant Kf UINT

2

N/A /
16

The force constant for a linear motor
(Active if Parameter Instance 195 = 1).
Range: 1 to 65535
Default: 16

Note: Set is not allowed if the drive is enabled.

198

Set

Rotary Inertia
Jm

UDINT

4

kg-cm

2

/ 65536

The rotor inertia for a rotary motor
(Active if Parameter Instance 195 = 0).
Range: 1 to 0x0ffffffff
Default: 49807

Note: Set is not allowed if the drive is enabled.

199

Set

Linear Motor
Mass

UDINT

4

kg /
65536

Mass of the moving part (rotor) of a linear motor
(Active if Parameter Instance 195 = 1).
Range: 1 to 0x0ffffffff
Default: 65536

Note: Set is not allowed if the drive is enabled.

200

Set

Total Mass

UDINT

4

kg /
65536

The mass of the load and moving part of a linear
motor
(Active if Parameter Instance 195 = 1).
Range: 0 to 0x0ffffffff
Default: 0

Note: Set is not allowed if the drive is enabled.

201

Set

Poles/ Revolution USINT

1

The number of motor poles per revolution
(Active if Parameter Instance 195 = 0).
Range: 2 to 100 (even numbers only)
Default: 8

Note: Set is not allowed if the drive is enabled.

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description