Pause homing, Abort homing, Preset select 0 to 5 – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 36: Preset select 5, Preset select 4, Preset select 3, Preset select 2, Preset select 1, Preset select 0, Abort homing pause

Advertising
background image

Publication 2098-RM004A-EN-P – August 2002

2-20

Programming Reference

Pause Homing

This bit temporarily pauses a homing sequence by decelerating to a
stop. The state of the input is continuously monitored to determine if
the motion should be stopped or if it may continue.

• 0 = Continue Homing (Inactive)
• 1 = Pause Homing

Note: This output requires an Indexing drive (e.g., 2098-DSD-xxxX).

Abort Homing

A transition from zero to one (0 -> 1) terminates a homing sequence.

Note: This output requires an Indexing drive (e.g., 2098-DSD-xxxX).

Preset Select 0 to 5

Preset Select 0 to 2 are used in combination to select a Preset Current,
Preset Velocity, Preset Position, or Preset Follower Gearing Ratio.
Preset Select 0 to 5 are used in combination to select an Index. The 64
possible binary combinations of the Preset Selects are shown in the
following table.

Preset

Preset
Select 5

Preset
Select 4

Preset
Select 3

Preset
Select 2

Preset
Select 1

Preset
Select 0

0

0

0

0

0

0

0

1

0

0

0

0

0

1

2

0

0

0

0

1

0

3

0

0

0

0

1

1

4

0

0

0

1

0

0

5

0

0

0

1

0

1

6

0

0

0

1

1

0

7

0

0

0

1

1

1

.
.
.

.
.
.

.
.
.

.
.
.

.
.
.

.
.
.

.
.
.

61

1

1

1

1

0

1

62

1

1

1

1

1

0

63

1

1

1

1

1

1

Advertising