Programming Reference

2-95

353

Get

Selected Index

USINT

1

The selected index.
Range: 0 to 63

354

Get

Index Count

UINT

The number of iterations remaining in the execution
of the index.
Range: 0 to 65535

355

Set

Auto-Start Index

USINT

1

Determines if the drive will begin executing the
selected index whenever the drive is enabled.
0 - Disable (default)
1 - Enable

356

Set

Abort Index
Decel

UDINT

4

Cnts /
Sec

2

The deceleration rate used to stop motion when the
Abort (Stop) input terminates an index move.
Range: 0 to 0x7fffffff
Default: 100000

357
and
367, 377, …,
967, 977, 987

Set

Index 0 Type

and
Index n Type
where n = 1-63

USINT

1

Selects the type of index move.
0 - Incremental (default)
1 - Absolute
2 - Registration
3 - Jog

358
and
368, 378, …,
968, 978, 988

Set

Index 0 Distance/
Position

and
Index n
Distance/Position
where n = 1-63

DINT

4

Cnts

For Incremental and Registration index moves,
specifies the relative distance of travel. For Absolute
moves, specifies the final position of the index
move. For a Jog index move, specifies the maximum
distance of travel.
Range: -0x7fffffff to 0x7fffffff
Default: 1000

359
and
369, 379, …,
969, 979, 989

Set

Index 0 Count

and
Index n Count
where n = 1-63

UINT

2

The number of times the index move will execute. If
it is set to zero (0), the index move will be executed
continuously.
Range: 0 to 65535
Default: 1

360

and
370, 380, …,
970, 980, 990

Set

Index 0 Dwell

and
Index n Dwell
where n = 1-63

UINT

2

mSec

The amount of time the drive holds position before
continuing to the next index.
Range: 0 to 65535
Default: 0

361

and
371, 381, …,
971, 981, 991

Set

Index 0
Registration
Distance

and
Index n
Registration
Distance
where n = 1-63

UDINT

4

Cnts

For Registration index moves, specifies the relative
distance of travel after a registration digital input is
detected.
Range: 0 to 0x7fffffff
Default: 1000

362

and
372, 382, …,
972, 982,
992

Set

Index 0 Velocity

and
Index n Velocity
where n = 1-63

UDINT

4

Cnts /
Sec

The commanded velocity used when executing the
index.
Range: 0 to 0x7fffffff
Default: 100000

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description