Programming Reference

2-47

IMPORTANT

If Explicit Messages are to be used frequently to
change the value of parameter objects, refer to
Parameter 114 - Parameter Object Write Behavior. By
default, an Explicit Message Set_Attribute_Single
service causes a nonvolatile memory (NVMEM)
write. However, the nonvolatile memory has a
limited number of write cycles. Change Parameter
114 - Parameter Object Write Behavior to 1 - No
NVMEM Writes to pr
event writing the nonvolatile
memory. Parameter values will continue to be
written to volatile memory (RAM).

Parameters 22–26, 63, 347–349, and 351 (which

have a No Action (0) selection) are not saved in
volatile or non-volatile memory.

Parameters 27–30, 95, 101–102, and 350 are not

saved in non-volatile memory, but are saved in
volatile memory.

Note: Explicit Get commands have no effect on
NVMEM.

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description

1

Set

Drive Name

SHORT_
STRING

1 byte
length
indicator, 1
byte per
character

The name of the drive, up to 32 characters long.

2

Get

Main Firmware
Version

SHORT_
STRING

1 byte
length
indicator, 1
byte per
character

The version of drive firmware, in the format
XX.YY.ZZ, where:

• XX = major revision
• YY = minor revision
• ZZ = maintenance revision (not displayed if zero).

3

Get

DN-SW Node
Address

USINT

1

DeviceNet Node Address (Mac_ID) switch setting.

4

Get

DN-SW Data
Rate

USINT

1

DeviceNet Data Rate switch setting.
0 - 125 kps
1 - 250 kps
2 - 500 kps
3 - Autobaud
4 - Programmable
5 - Programmable
6 - Programmable
7 - Programmable
8 - Programmable
9 - Programmable