Publication 2098-RM004A-EN-P – August 2002

2-90

Programming Reference

310

Set

Preset Position 1
Accel

UDINT

4

Cnts /
Sec

2

The acceleration rate used to change to a higher
velocity during a Preset Position 1 move.
Range: 0 to 0x7fffffff
Default: 100000

311

Set

Preset Position 1
Decel

UDINT

4

Cnts /
Sec

2

The deceleration rate used to change to a lower
velocity during a Preset Position 1 move.
Range: 0 to 0x7fffffff
Default: 100000

312

Set

Preset Position 2

DINT

4

Cnts

If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0

313

Set

Preset Position 2
Velocity

UDINT

4

Cnts /
Sec

The velocity used during a Preset Position 2 move.
Range: 0 to 0x7fffffff
Default: 100000

314

Set

Preset Position 2
Accel

UDINT

4

Cnts /
Sec

2

The acceleration rate used to change to a higher
velocity during a Preset Position 2 move.
Range: 0 to 0x7fffffff
Default: 100000

315

Set

Preset Position 2
Decel

UDINT

4

Cnts /
Sec

2

The deceleration rate used to change to a lower
velocity during a Preset Position 2 move.
Range: 0 to 0x7fffffff
Default: 100000

316

Set

Preset Position 3

DINT

4

Cnts

If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0

317

Set

Preset Position 3
Velocity

UDINT

4

Cnts /
Sec

The velocity used during a Preset Position 3 move.
Range: 0 to 0x7fffffff
Default: 100000

318

Set

Preset Position 3
Accel

UDINT

4

Cnts /
Sec

2

The acceleration rate used to change to a higher
velocity during a Preset Position 3 move.
Range: 0 to 0x7fffffff
Default: 100000

319

Set

Preset Position 3
Decel

UDINT

4

Cnts /
Sec

2

The deceleration rate used to change to a lower
velocity during a Preset Position 3 move.
Range: 0 to 0x7fffffff
Default: 100000

Parameter Object,
Instances ID = 1- 1059

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description